System Variable ANNOMONITOR¶
Turns on and off the Annotation Monitor. When enabled, the Annotation Monitor notifies you if annotation entities, such as Dimensions and Leaders, loose the associativity to their related entities. A yellow icon with an exclamation mark (
) displays next to not related annotation entities.
Values
0 |
Turns off the Annotation Monitor |
1, -1 |
Turn the Annotation Monitor on (1) and off (-1). The AnnoMonitor button on the status bar toggles between 1 and -1. |
2, -2 |
By default, it is off. The Annotation Monitor automatically turns on (ANNOMONITOR=2) when an update event occures in the drawing. The AnnoMonitor button on the status bar toggles between 2 and -2. |
Properties
Type |
Integer |
Default |
-2 |
Status |
Read/Write |
Saved |
In the drawing |
Related Variables